EAC-H Unit B | Elevator Air Conditioner/Heater Integrated System

The Model EAC-H Elevator Air Conditioner/Heater Integrated System offers high-capacity performance with Unit B. Designed for top-mounted elevator installation, this compact and rugged system integrates cooling, heating, and protection features suitable for larger cab environments and more demanding climate control needs.

General Features
  • Unit mounts easily in virtually any position on top of the elevator
  • Self-contained, packaged design for easy installation
  • Compact rotary compressor saves space and weight
  • Rated at 14,000 BTUH nominal cooling capacity
  • Mechanical heat/cool thermostat mounted in return air flex duct for secure settings and more accurate temperature sensing
  • 15' umbilical for remote thermostat mounting; optional automatic changeover heat/cool thermostat available
  • Standard 1600 Watt electric heater delivers 5,600 BTUH heat capacity
  • Fan can be set to operate continuously for improved air circulation and filtration
  • Compressor hermetically sealed at factory for leak-proof refrigerant flow and efficient operation
  • Black finish on supply air diverter conceals it in the gap between the false ceiling and interior wall
  • Compressor and outer cabinet mounted on shock absorbing rubber for added durability and noise reduction
  • Long-lasting copper tubing with shock loops to strengthen vibration resistance
  • Gas-flux brazed joints on the tubing to resist corrosion
  • Start circuit with capacitor and relay makes starting easier on the compressor
  • All galvanized steel construction of the outer cabinet ensures corrosion resistance
  • Heavy-duty, galvanized steel drain pan with bronze-brazed and powder-coated corners
  • Enhanced freeze protection with high/low pressure switches
  • 4-pin connector for easy thermostat hookup
  • Field wiring to lugs on the Printed Circuit Board
  • Washable filter drops into the return air bonnet
Technical Specifications
Specification Unit B
Cooling Capacity (BTUH) 14,000
Airflow Rate (CFM) 450
Electric Heater Capacity (BTUH) 5,600
Freeze Protection Enhanced with high/low pressure switches
Test Conditions
Note Description
* Air conditioner only. Does not include condensate evaporator.
** Cooling A.R.I. Standard Conditions: 80°F DB/67°F WB Indoor, 95°F DB Outdoor at 115VAC.
*** Cooling A.R.I. Standard Conditions: 95°F DB/71°F WB Indoor, 115°F DB Outdoor at 103.5VAC.